Users Guide
Using the Storage Management Service 173
omconfig Blink Physical Disk
You can blink the light (light emitting diode or LED display) on one or more
physical disks attached to a controller. Use the following omconfig command
syntax to blink one or more physical disks.
Complete Syntax
action=blink controller=ID action=blink
controller=id pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the physical
disk.
To obtain these values, enter omreport storage controller to display the
controller IDs and then enter omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, you want to blink physical disk 0 on connector 0 of controller 1.
On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers
To blink the physical disk described in this example, enter:
omconfig storage pdisk action=blink controller=1
pdisk=0:0
action=offline controller=id pdisk=<PDISKID>
action=online controller=id pdisk=<PDISKID>
action=assignglobalhotspare controller=id pdisk=<PDISKID>
assign=<yes|no>
action=rebuild controller=id pdisk=<PDISKID>
action=cancelrebuild controller=id pdisk=<PDISKID>
action=removedeadsegments controller=id pdisk=<PDISKID>
Table 6-23. omconfig Physical Disk Commands (continued)
Required Command Levels
(1, 2, 3)
Optional name=value pairs