SNMP Reference Guide
586 Traps
AC Power Cord Traps
The AC power cord sensor monitors the presence of AC power for an AC power cord. AC power cord
traps provide status and warning information for power cords that are part of an AC power switch, if your
system supports AC switching.
Table 25-12. AC Power Cord Traps
Trap ID Description Severity Cause
AC Power Cord No Power Nonredundant
1501 AC power cord is not being
monitored
Sensor location: <
Location in
chassis
>
Chassis location: <
Name of chassis
>
Information The AC power cord status is not being
monitored. This occurs when a system’s
expected AC power configuration is set
to nonredundant. The sensor location
and chassis location information are
provided.
AC Power Cord Normal
1502 AC power has been restored
Sensor location: <
Location in
chassis
>
Chassis location: <
Name of chassis
>
Information An AC power cord that did not have
AC power has had the power restored.
The sensor location and chassis location
information are provided.
AC Power Cord Failure
1504 AC power has been lost
Sensor location: <
Location in
chassis
>
Chassis location: <
Name of chassis
>
Error An AC power cord has lost its power.
The sensor location and chassis location
information are provided.