SNMP Reference Guide

Storage Management Group 541
Battery Max Charge Count
Battery Nexus ID
Battery Predicted Capacity
Battery Next Learn Time
Name batteryMaxChargeCount
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.8
Description The maximum number of charges that can be applied to the battery.
Syntax Integer
Access Read-only
Name batteryNexusID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.9
Description Durable unique ID for this EMM.
Syntax DisplayString
Access Read-only
Name batteryPredictedCapacity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.10
Description Displays the battery's ability to be charged.
Possible values:
1: Failed - The battery cannot be charged and needs to be replaced.
2: Ready - The battery can be charged to full capacity.
4: Unknown - The battery is completing a Learn cycle. The charge capacity of the
battery cannot be determined until the Learn cycle is complete.
Syntax Integer
Access Read-only
Name batteryNextLearnTime
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.11
Description Indicates the time (in hours) the next learn cycle must be executed
Syntax Integer
Access Read-only