Read me
file:///T|/htdocs/SOFTWARE/svradmin/5.2/en/readme/readme_sa.txt[10/23/2012 1:34:18 PM]
running Server Administrator and then uninstall Server Administrator,
the changed threshold value becomes the default threshold value.
* When modifying the warning threshold settings, the values are stored
in the firmware as discrete integer values and scaled for display.
If the modified value is not a discrete integer, it may change when
saved.
* Fan redundancy can have the following states:
Fully Redundant: The sensors display this status, if all the fans
in the system are present and are in a non-failure state.
OR
Redundancy Lost: The sensors display this status, whenever any
system fan fails or is removed from the chassis.
Additionally, on PowerEdge 6800, the sensors will report a fan
redundancy status of "Redundancy Lost" in the following scenarios:
- A power supply is removed and a power supply fan blank is not
inserted.
- A power supply fan blank is present but failed.(134157)
* If a system with memory redundancy enabled enters a "redundancy
lost" state, it may not be apparent which memory module is the
cause. If you cannot determine which DIMM to replace, see the
"switch to spare memory detected" log entry in the ESM system
log to find which memory module failed.
* If you run Server Administrator while the system is in OS Install
Mode, memory may be reported incorrectly by Server Administrator.
To avoid this issue, you must disable OS Install Mode before
running Server Administrator.
* If you have to uninstall and reinstall the operating system SNMP
service, then reinstall Server Administrator as well, so that the
Server Administrator SNMP agents are registered with the operating
system SNMP agent.
* Server Administrator Device Drivers for Linux
Server Administrator includes two device drivers for Linux: Dell
Systems Management Base Driver (dcdbas) and Dell BIOS Update Driver
(dell_rbu). Server Administrator uses these drivers to perform its
systems management functions. Depending on the system, Server
Administrator loads one or both of these drivers if required.
These drivers have been released as open source under the GNU
General Public License v2.0. They are available in Linux kernels
from kernel.org starting with kernel 2.6.14.
Red Hat Enterprise Linux: