Read me
file:///T|/htdocs/SOFTWARE/svradmin/5.2/en/readme/readme_sa.txt[10/23/2012 1:34:18 PM]
* On PowerEdge 750 systems, if you disable the Power button in
Server Administrator, the system does not power cycle or power down
in the event of system instability and/or blue screens. In such
cases, you need to physically remove the power cord from the system
to power down the unit. As the startup and recovery options in the
operating system override those of Server Administrator, you need
to configure them in the operating system to restart the system
after a crash.
NOTE: The above situation is applicable only when the "reboot"
option in the startup and recovery options is disabled. If the
"reboot" option is enabled, the system will automatically reboot
and you will not be forced to shut down by removing the power cord.
(126837)
* While browsing through IT Assistant, if the SNMP protocol is
disabled and the CIM protocol is enabled, the redundancy status is
shown as lost even though the system has full redundancy. To
confirm the correct state of the system, use the Server
Administrator user interface.
* If you have a RAID 1 virtual disk on a CERC SATA 1.5/6ch
controller, performing a Format or Split Mirror operation
may fail. Dell is working to resolve this problem.
* When issuing the Server Administrator command line "omreport
system version -outc <filename>", be sure to specify an absolute
path name for the output file, for example, "c:\out.txt"; otherwise,
the output file will be empty.
* Issuing the "omreport system esmlog/alertlog/cmdlog -fmt tbl"
command on the CLI can result in XML parsing errors if the size
of the log is very large. Use the GUI or the "omreport system
esmlog/alertlog/cmdlog" CLI command to view the contents of
the log.(124997)
* For complex "omconfig" CLI commands that contain multiple commands
in one command line, the CLI may report a success status for the
command even if part of the command failed. To avoid this issue,
run only one command per command line. The current settings can be
confirmed by performing the corresponding "omreport" command.
* Some complex "omconfig" CLI commands that contain multiple set
operations have been modified to avoid the above problem. If, while
executing a CLI command you receive the message "Error! Illegal
combination of parameters", modify your command into several simpler
commands. Each command should change only one setting.
* When running Server Administrator on a system with a Traditional
Chinese operating system, the Server Administrator pages are
displayed in Simplified Chinese. To view Server Administrator in
English, go to your browser language preference page and change