Messages Reference Guide
Storage Management Message Reference 91
2201 A global hot spare
failed.
Warning /
Non-critical
Cause: The controller is not able to
communicate with a disk that is assigned as a
dedicated hot spare. The disk may have been
removed. There may also be a bad or loose
cable.
Action: Check if the disk is healthy and that
it has not been removed. Check the cables. If
necessary, replace the disk and reassign the
hot spare.
None 903
2202 A global hot spare
has been removed.
Ok / Normal Cause: The controller is unable to
communicate with a disk that is assigned as a
global hot spare. The disk may have been
removed. There may also be a bad or loose
cable.
Action: Check if the disk is healthy and that
it has not been removed. Check the cables. If
necessary, replace the disk and reassign the
hot spare.
None 901
2203 A dedicated hot
spare failed.
Warning /
Non-critical
Cause: The controller is unable to
communicate with a disk that is assigned as a
dedicated hot spare. The disk may have failed
or been removed. There may also be a bad or
loose cable.
Action: Check if the disk is healthy and that
it has not been removed. Check the cables. If
necessary, replace the disk and reassign the
hot spare.
None 903
2204 A dedicated hot
spare has been
removed.
Ok / Normal Cause: The controller is unable to communicate
with a disk that is assigned as a dedicated hot
spare. The disk may have been removed.
There may also be a bad or loose cable.
Action: Check if the disk is healthy and that
it has not been removed. Check the cables. If
necessary, replace the disk and reassign the
hot spare.
None 901
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers