Messages Reference Guide
Storage Management Message Reference 113
2356 SAS SMP
communications
error %1.
Critical /
Failure /
Error
Cause: The %1 indicates a substitution
variable. The text for this substitution
variable is generated by the firmware and is
displayed with the alert in the Alert Log. This
text can vary depending on the situation. The
reference to SMP in this text refers to SAS
Management Protocol.
Action: There may be a SAS topology error.
See the hardware documentation for
information on correct SAS topology
configurations. There may be problems with
the cables such as a loose connection or an
invalid cabling configuration. See the
hardware documentation for information on
correct cabling configurations. Check if the
firmware is a supported version.
None 754
2357 SAS expander
error: %1
Critical /
Failure /
Error
Cause: The %1 indicates a substitution
variable. The text for this substitution
variable is generated by the firmware and is
displayed with the alert in the Alert Log. This
text can vary depending on the situation.
Action: There may be a problem with the
enclosure. Check the health of the enclosure
and its components. by selecting the enclosure
object in the tree view. The Health subtab
displays a red "X" or yellow exclamation point
for enclosure components that are failed or
degraded. See the enclosure documentation
for more information.
None 754
2358 The battery charge
cycle is complete.
Ok / Normal Cause: This alert is for informational purposes.
Action: None.
None 1151
2359 The physical disk is
not certified.
Warning /
Non-critical
Cause: The physical disk does not comply
with the standards set by Dell and is not
supported.
Action: Replace the physical disk with a
physical disk that is supported.
None 903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers