112 Storage Management Message Reference
2348 The rebuild failed
due to errors on the
target physical disk.
Critical /
Failure /
Error
Cause: You are attempting to rebuild data on
a disk that is defective.
Action: Replace the target disk. If a rebuild
does not automatically start after replacing
the disk, initiate the Rebuild task. You may
need to assign the new disk as a hot spare to
initiate the rebuild.
None 904
2349 A bad disk block
could not be
reassigned during a
write operation.
Critical /
Failure /
Error
Cause: A write operation could not complete
because the disk contains bad disk blocks
that could not be reassigned. Data loss may
have occurred and data redundancy may also
be lost.
Action: Replace the disk.
None 904
2350 There was an
unrecoverable disk
media error during
the rebuild.
Critical /
Failure /
Error
Cause: The rebuild encountered an
unrecoverable disk media error.
Action: Replace the disk.
None 904
2351 A physical disk is
marked as missing.
Ok / Normal Cause: This alert is for informational purposes.
Action: None.
2352 901
2352 A physical disk that
was marked as
missing has been
replaced.
Ok / Normal Cause: This alert is for informational purposes.
Action: None.
Clear
event
901
2353 The enclosure
temperature has
returned to normal.
Ok / Normal Cause: This alert is for informational purposes.
Action: None.
Clear
event
851