2299 Bad PHY %1 Critical /
Failure /
Error
Cause: There is a problem with a physical
connection or PHY. The %1 indicates a
substitution variable. The text for this
substitution variable is displayed with the
alert in the Alert Log and can vary depending
on the situation.
Action: Contact Dell technical support.
None 854
2300 The enclosure is
unstable.
Critical /
Failure /
Error
Cause: The controller is not receiving a
consistent response from the enclosure.
There could be a firmware problem or an
invalid cabling configuration. If the cables are
too long, they will degrade the signal.
Action: Power down all enclosures attached
to the system and reboot the system. If the
problem persists, upgrade the firmware to the
latest supported version. You can download
the most current version of the driver and
firmware from support.dell.com. Make sure
the cable configuration is valid. See the
hardware documentation for valid cabling
configurations.
None 854
2301 The enclosure has a
hardware error.
Critical /
Failure /
Error
Cause: The enclosure or an enclosure
component is in a Failed or Degraded state.
Action: Check the health of the enclosure
and its components. Replace any hardware
that is in a Failed state. See the hardware
documentation for more information.
None 854
2302 The enclosure is not
responding.
Critical /
Failure /
Error
Cause: The enclosure or an enclosure
component is in a Failed or Degraded state.
Action: Check the health of the enclosure
and its components. Replace any hardware
that is in a Failed state. See the hardware
documentation for more information.
None 854
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers