User's Manual

omconfig: Managing Components Using the Instrumentation Service 93
Source
At present, source=snmptraps is a required name=value pair because SNMP is currently the only
supported source of event notification for your system’s components.
omconfig system events source=snmptraps
Type
The event type refers to the name of the component(s) involved in the event. Table 4-24 shows the valid
parameters for system event types.
Severity
In the context of configuring events, severity determines how severe an event must be before Server
Administrator notifies you of the event for a component type. When there are multiple components of
the same type in the same system chassis, you can also specify whether you want to be notified for event
severity according to the number of the component by using the index=
<n> parameter. Table 4-25 shows
the valid severity parameters.
Table 4-24. System Event Type Parameters
name=value pair Description
type=accords Configures events for AC power cords.
type=battery Configures events for battery.
type=all Configures events for all device types.
type=currents Configures events for amperage.
type=fanenclosures Configures events for fan enclosures.
type=fans Configures events for fans.
type=intrusion Configures events for chassis intrusion.
type=log Configures events for logs.
type=memory Configures events for memory.
type=powersupplies Configures events for power supplies.
type=redundancy Configures events for redundancy.
type=temps Configures events for temperatures.
type=volts Configures events for voltages.