User's Manual

88 omconfig: Managing Components Using the Instrumentation Service
Components and Events for Which You Can Set Alert Actions
Table 4-20 lists the components and the events for which you can set alert actions. Components are listed in
alphabetical order, except that warning events always precede failure events for a component.
clearall=true Clears all actions for this event.
execappath=<string> Sets the fully qualified path and filename of the application you want to
execute in case of an event for the component described in this window.
execapp=false Disables the executable application.
Table 4-20. Events for Which You Can Set Alert Actions
Event Name Description
event=batterywarn Sets actions when a battery probe detects a warning value.
event=batteryfail Sets actions when a battery probe detects a failure value.
event=currentwarn Sets actions when a current probe detects a warning value.
event=currentfail Sets actions when a current probe detects a failure value.
event=fanwarn Sets actions when a fan probe detects a warning value.
event=fanfail Sets actions when a fan probe detects a failure value.
event=hardwarelogwarn Sets actions when a hardware log detects a warning value.
event=hardwarelogfull Sets actions when a hardware log is full.
event=intrusion Sets actions when a chassis intrusion event is detected.
event=memprefail Sets actions when a memory probe detects a prefailure value.
event=memfail Sets actions when a memory probe detects a failure value.
event=powersupply Sets actions when a power supply probe detects a failure value.
event=powersupplywarn Sets actions when a power supply probe detects a warning value.
event=processorwarn Sets actions when a processor probe detects a warning value.
event=processorfail Sets actions when a processor probe detects a failure value.
event=redundegrad Sets actions when a redundant component becomes inoperative, resulting in
less than full redundancy for that component.
event=redunlost Sets actions when one or more redundant components become inoperative,
resulting in a lost or a "no redundant components working" condition for
that component.
event=tempwarn Sets actions when a temperature probe detects a warning value.
event=tempfail Sets actions when a temperature probe detects a failure value.
Table 4-19. Alert Actions You Can Set for Warning and Failure Events (continued)
Alert Action Setting Description