User's Manual
Using the Storage Management Service 181
Example for SCSI, SATA, and ATA Controllers:
In this example, temperature probe 3 resides in the enclosure attached to connector 2 on controller 1.
To reset the thresholds for temperature probe 3 to the default values, enter:
omconfig storage enclosure action=resettempprobes controller=1
enclosure=2 index=3
omconfig Set All Temperature Probe Thresholds
Use the following omconfig command syntax to set the minimum and maximum warning temperature
thresholds for all temperature probes in the enclosure.
NOTE: This command is not supported on SCSI RAID controllers.
Complete Syntax
omconfig storage enclosure action=setalltempprobes controller=id
enclosure=<ENCLOSUREID> minwarn=n maxwarn=n
where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.
Example Syntax
For example, you may want to specify the minimum and maximum warning thresholds for all
temperature probes to 10 and 40
° Celsius.
Example for SAS Controllers
In this example, the temperature probes reside in enclosure 3 attached to connector 2 on controller 1.
To set the thresholds for all temperature probes to 10 and 40
° Celsius, enter:
omconfig storage enclosure action=setalltempprobes controller=1
enclosure=2:3 minwarn=10 maxwarn=40
omconfig Reset All Temperature Probe Thresholds
Use the following omconfig command syntax to reset the minimum and maximum warning temperature
thresholds back to their default value for all temperature probes in the enclosure.
NOTE: This command is not supported on SCSI RAID controllers.
Complete Syntax
omconfig storage enclosure action=resetalltempprobes controller=id
enclosure=<ENCLOSUREID>
where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.