User's Manual

166 Using the Storage Management Service
omconfig Physical Disk Commands
The following sections provide the omconfig command syntax required to execute physical disk tasks.
omconfig Blink Physical Disk
You can blink the light (light emitting diode or LED display) on one or more physical disks attached to a
controller. Use the following omconfig command syntax to blink one or more physical disks.
Complete Syntax
action=blink controller=ID action=blink controller=id pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the physical disk.
To obtain these values, enter omreport storage controller to display the controller IDs and then enter
omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, you want to blink physical disk 0 on connector 0 of controller 1. On a SAS controller, the
physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers:
To blink the physical disk described in this example, enter:
omconfig storage pdisk action=blink controller=1 pdisk=0:0
Table 8-23. omconfig Physical Disk Commands
Required Command Levels (1, 2, 3) Optional name=value pairs
omconfig storage pdisk
action=blink controller=id pdisk=<PDISKID>
action=unblink controller=id pdisk=<PDISKID>
action=remove controller=id pdisk=<PDISKID>
action=initialize controller=id pdisk=<PDISKID>
action=offline controller=id pdisk=<PDISKID>
action=online controller=id pdisk=<PDISKID>
action=assignglobalhotspare controller=id pdisk=<PDISKID>
assign=<yes|no>
action=rebuild controller=id pdisk=<PDISKID>
action=cancelrebuild controller=id pdisk=<PDISKID>
action=removedeadsegments controller=id pdisk=<PDISKID>