Reference Guide

Storage Management Message Reference 99
2280 A disk media error
has been corrected.
Ok / Normal Cause: A disk media error was detected
while the controller was completing a
background task. A bad disk block was
identified. The disk block has been
remapped.
Action: Consider replacing the disk. If you
receive this alert frequently, be sure to replace
the disk. You should also routinely back up
your data.
None 1201
2281 Virtual disk has
inconsistent data.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 1201
2282 Hot spare SMART
polling failed.
Critical /
Failure /
Error
Cause: The controller firmware attempted a
SMART polling on the hot spare but was
unable to complete it. The controller has lost
communication with the hot spare.
Action: Check the health of the disk assigned
as a hot spare. You may need to replace the
disk and reassign the hot spare. Make sure the
cables are attached securely. See the Cables
Attached Correctly section in the
Dell OpenManage Server Administrator
Storage Management User’s Guide for more
information on checking the cables.
None 904
2283 A redundant path is
broken.
Warning /
Non-critical
Cause: The controller has two connectors
that are connected to the same enclosure.
The communication path on one connector
has lost connection with the enclosure. The
communication path on the other connector
is reporting this loss.
Action: Make sure the cables are attached
securely. Make sure both EMMs are healthy.
2284 903
2284 A redundant path
has been restored.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
Clear
event
901
2285 A disk media error
was corrected during
recovery.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 901
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers