Reference Guide
78 Storage Management Message Reference
2121 Device returned to
normal
Ok / Normal Cause: This alert is for informational purposes.
A device that was previously in an error state
has returned to a normal state.
For example, if an enclosure became too hot
and subsequently cooled down, then you may
receive this alert.
Action: None
Clear
event
752
802
852
902
952
1002
1052
1102
1152
1202
2122 Redundancy
degraded
Warning /
Non-critical
Cause: One or more of the enclosure
components has failed.
For example, a fan or power supply may have
failed. Although the enclosure is currently
operational, the failure of additional
components could cause the enclosure to fail.
Action: Identify and replace the failed
component. To identify the failed component,
select the enclosure in the tree view and click
the Health subtab. Any failed component will
be identified with a red "X" on the enclosure’s
Health subtab. Alternatively, you can select
the Storage object and click the Health
subtab. The controller status displayed on the
Health subtab indicates whether a controller
has a failed or degraded component.
See the enclosure documentation for
information on replacing enclosure
components and for other diagnostic
information.
2124 1305
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers