Reference Guide
System Event Log Messages for IPMI Systems 51
Memory Events
The memory modules can be configured in different ways in particular systems. These messages monitor
the status, warning, and configuration information about the memory modules in the system.
Hardware Log Sensor Events
The hardware logs provide hardware status messages to the system management software. On particular
systems, the subsequent hardware messages are not displayed when the log is full. These messages
provide status and warning messages when the logs are full.
Table 3-8. Memory Events
Event Message Severity Cause
Memory RAID redundancy
degraded.
Information This event is generated when there is a memory failure in a
RAID-configured memory configuration.
Memory RAID redundancy
lost.
Critical This event is generated when redundancy is lost in a
RAID-configured memory configuration.
Memory RAID redundancy
regained
Information This event is generated when the redundancy lost or degraded
earlier is regained in a RAID-configured
memory configuration.
Memory Mirrored
redundancy degraded.
Information This event is generated when there is a memory failure in a
mirrored memory configuration.
Memory Mirrored
redundancy lost.
Critical This event is generated when redundancy is lost in a mirrored
memory configuration.
Memory Mirrored
redundancy regained.
Information This event is generated when the redundancy lost or degraded
earlier is regained in a mirrored memory configuration.
Memory Spared redundancy
degraded.
Information This event is generated when there is a memory failure in a
spared memory configuration.
Memory Spared redundancy
lost.
Critical This event is generated when redundancy is lost in a spared
memory configuration.
Memory Spared redundancy
regained.
Information This event is generated when the redundancy lost or degraded
earlier is regained in a spared memory configuration.
Table 3-9. Hardware Log Sensor Events
Event Message Severity Cause
Log full detected. Critical This event is generated when the SEL device detects that
only one entry can be added to the SEL before it is full.
Log cleared. Information This event is generated when the SEL is cleared.