Reference Guide
112 Storage Management Message Reference
2345 The virtual disk
initialization failed.
Critical /
Failure /
Error
Cause: The controller cannot communicate
with the attached devices. A disk may be
removed or contain errors. The cables may
also be loose or defective.
Action: Check the health of attached devices.
Review the Alert Log for significant events
and make sure the cables are attached
securely. See the Cables Attached Correctly
section in the Dell OpenManage Server
Administrator Storage Management
User’s Guide for more information on
checking the cables.
None 1204
2346 Error occurred: %1 Warning /
Non-critical
Cause: A physical device may have an error.
The %1 indicates a substitution variable. The
text for this substitution variable is generated
by the firmware and is displayed with the
alert in the Alert Log. This text can vary
depending on the situation.
Action: Verify the health of attached devices.
Review the Alert Log for significant events.
Run the PHY integrity diagnostic tests. You
may need to replace faulty hardware. Make
sure the cables are attached securely. See the
hardware documentation for more
information.
None 903
2347 The rebuild failed
due to errors on the
source physical disk.
Critical /
Failure /
Error
Cause: You are attempting to rebuild data
that resides on a defective disk.
Action: Replace the source disk and restore
from backup.
None 904
2348 The rebuild failed
due to errors on the
target physical disk.
Critical /
Failure /
Error
Cause: You are attempting to rebuild data on
a disk that is defective.
Action: Replace the target disk. If a rebuild
does not automatically start after replacing
the disk, initiate the Rebuild task. You may
need to assign the new disk as a hot spare to
initiate the rebuild.
None 904
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers