Reference Guide
Storage Management Message Reference 111
2340 The BGI completed
with uncorrectable
errors.
Critical /
Failure /
Error
Cause: The BGI task encountered errors that
cannot be corrected. The virtual disk contains
physical disks that have unusable disk space
or disk errors that cannot be corrected.
Action: Replace the physical disk that
contains the disk errors. Review other alert
messages to identify the physical disk that
has errors. If the virtual disk is redundant, you
can replace the physical disk and continue
using the virtual disk. If the virtual disk is
non-redundant, you may need to recreate the
virtual disk after replacing the physical disk.
After replacing the physical disk, run Check
Consistency to check the data.
None 1204
2341 The Check
Consistency made
corrections and
completed.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 1201
2342 The Check
Consistency found
inconsistent parity
data. Data
redundancy may be
lost.
Warning /
Non-critical
Cause: The data on a source disk and the
redundant data on a target disk is
inconsistent.
Action: Restart the Check Consistency task.
If you receive this alert again, check the
health of the physical disks included in the
virtual disk. Review the alert messages for
significant alerts related to the physical disks.
If you suspect that a physical disk has a
problem, replace it and restore from backup.
None 1203
2343 The Check
Consistency logging
of inconsistent parity
data is disabled.
Warning /
Non-critical
Cause: The Check Consistency can no longer
report errors in the parity data.
Action: See the hardware documentation for
more information.
None 1203
2344 The virtual disk
initialization
terminated.
Warning /
Non-critical
Cause: A user has cancelled the virtual disk
initialization.
Action: Restart the initialization.
None 1203