Reference Guide
Storage Management Message Reference 103
2301 The enclosure has a
hardware error.
Critical /
Failure /
Error
Cause: The enclosure or an enclosure
component is in a Failed or Degraded state.
Action: Check the health of the enclosure
and its components. Replace any hardware
that is in a Failed state. See the hardware
documentation for more information.
None 854
2302 The enclosure is not
responding.
Critical /
Failure /
Error
Cause: The enclosure or an enclosure
component is in a Failed or Degraded state.
Action: Check the health of the enclosure
and its components. Replace any hardware
that is in a Failed state. See the hardware
documentation for more information.
None 854
2303 The enclosure
cannot support both
SAS and SATA
physical disks.
Physical disks may
be disabled.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 851
2304 An attempt to hot
plug an EMM has
been detected. This
type of hot plug is
not supported.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 751
2305 The physical disk is
too small to be used
for a rebuild.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 901
2306 Bad block table is
80% full.
Warning /
Non-critical
Cause: The bad block table is used for
remapping bad disk blocks. This table fills,
as bad disk blocks are remapped. When the
table is full, bad disk blocks can no longer be
remapped, and disk errors can no longer be
corrected. At this point, data loss can occur.
The bad block table is now 80% full.
Action: Back up your data. Replace the
disk generating this alert and restore from
back up.
None 903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers