CIM Reference Guide
44 CIM_LogicalElement
CIM_CoolingDevice
The CIM_CoolingDevice class described in Table 3-18 contains a set of devices that work to keep the
ambient internal temperature of the system at a safe value.
Table 3-17. CIM_WatchDog Properties
Class Name: CIM_WatchDog
Parent Class: CIM_LogicalDevice
Property Description Data Type
MonitoredEntity Indicates the entity that is currently being monitored by the
watchdog feature. This property is used to identify the module
that is responsible for rearming the watchdog at periodic
intervals. Values for the MonitoredEntity property are as
follows:
1
Unknown
2
Other
3
Operating System
uint16
MonitoredEntity Description A string describing additional textual information about the
monitored entity.
string
TimeoutInterval Indicates the time-out interval used by the watchdog, in
microseconds.
uint32
TimerResolution Indicates the resolution of the watchdog timer. For example, if
this value is 100, then the timer can expire anytime between
–100 microseconds and +100 microseconds.
uint32
Table 3-18. CIM_CoolingDevice Properties
Class Name: CIM_CoolingDevice
Parent Class: CIM_LogicalDevice
Property Description Data Type
ActiveCooling Specifies whether the device provides active (as opposed to passive) cooling. Boolean
CIM_
ManagedSystemElement
CIM_LogicalElement
CIM_LogicalDevice
CIM_CoolingDevice