16 CIM_PhysicalElement
CIM_PhysicalFrame
The CIM_PhysicalFrame class described in Table 2-3 contains other frame enclosures such as racks and
chassis. Properties like VisibleAlarm or AudibleAlarm, and data related to security breaches are also
members of this class.
Table 2-3. CIM_Physical Frame Properties
Class Name: CIM_PhysicalFrame
Parent Class: CIM_PhysicalPackage
Property Description Data Type
LockPresent Indicates whether the frame is protected with a lock. Boolean
AudibleAlarm Indicates whether the frame is equipped with an audible alarm. Boolean
VisibleAlarm Indicates that the equipment includes a visible alarm. Boolean
SecurityBreach An enumerated, integer-valued property indicating that a physical
breach of the frame is in progress. Values for the SecurityBreach
property are as follows:
1
Other
2
Unknown
3
No breach
4
Breach attempted
5
Breach successful
uint16
IsLocked Indicates that the frame is currently locked. Boolean
CIM_PhysicalPackage
CIM_PhysicalFrame
CIM_
ManagedSystemElement
CIM_PhysicalElement