Reference Guide
654 Storage Management Alert Reference
2356 SAS
Management
Protocol
(SMP)
communi-
cations error
%1. The %1
indicates a
substitution
variable. The
text for this
substitution
variable is
displayed with
the alert in the
Alert Log and
can vary
depending on
the situation.
Critical/
Failure/
Error
Cause: The text for this alert is generated by the
firmware and can vary depending on the situation.
The reference to SMP in this text refers to SAS
Management Protocol.
Action: There may be a SAS topology error. See the
hardware documentation for information on correct
SAS topology configurations. There may be problems
with the cables such as a loose connection or an invalid
cabling configuration. See the hardware
documentation for information on correct cabling
configurations. Verify that the firmware is a supported
version.
754 None
2357 SAS expander
error: %1. The
%1 indicates a
substitution
variable. The
text for this
substitution
variable is
displayed with
the alert in the
Alert Log and
can vary
depending on
the situation.
Critical/
Failure/
Error
Cause: The text for this alert is generated by the
firmware and can vary depending on the situation.
Action: There may be a problem with the enclosure.
Verify the health of the enclosure and its components.
To verify the health of the enclosure, select the
enclosure object in the tree view. The Health subtab
displays a red "X" or yellow exclamation point for
enclosure components that are failed or degraded.
See the enclosure documentation for more
information.
754 None
2358 The battery
charge cycle is
complete.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
1151 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number