Reference Guide
Storage Management Alert Reference 653
2350 There was an
unrecoverable
disk media
error during
the rebuild.
Critical/
Failure/
Error
Cause: The rebuild encountered an unrecoverable disk
media error.
Action: Replace the disk.
904 None
2351 A physical disk
is marked as
missing.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
901 None
2352 A physical disk
that was
marked as
missing has
been replaced.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
901 None
2353 The enclosure
temperature
has returned
to normal.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
851 None
2354 Enclosure
firmware
download in
progress.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
851 None
2355 Enclosure
firmware
download
failed.
Wa rn ing/
Non-critical
Cause: The system was unable to download firmware to
the enclosure. The controller may have lost
communication with the enclosure. There may have
been problems with the data transfer or the download
media may be corrupt.
Action: Attempt to download the enclosure firmware
again. If problems continue, verify that the controller
can communicate with the enclosure. Make sure that
the enclosure is powered on. Check the cables. Verify
the health of the enclosure and its components. To
verify the health of the enclosure, select the enclosure
object in the tree view. The Health subtab displays a
red "X" or yellow exclamation point for enclosure
components that are failed or degraded.
853 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number