Reference Guide
Storage Management Alert Reference 651
2340 The
background
initialization
(BGI)
completed
with
uncorrectable
errors.
Critical/
Failure/
Error
Cause: The BGI task encountered errors that cannot be
corrected. The virtual disk contains array disks that
have unusable disk space or disk errors that cannot be
corrected.
Action: Replace the array disk that contains the disk
errors. Review other alert messages to identify the array
disk that has errors. If the virtual disk is redundant, you
can replace the array disk and continue using the
virtual disk. If the virtual disk is non-redundant, you
may need to recreate the virtual disk after replacing the
array disk. After replacing the array disk, run a Check
Consistency to verify the data.
1204 None
2341 The Check
Consistency
made
corrections
and
completed.
OK/Normal/
Informational
Cause: This alert is provided for informational
purposes.
Action: None.
1201 None
2342 The Check
Consistency
found
inconsistent
parity data.
Data
redundancy
may be lost.
Wa rn ing/
Non-critical
Cause: The data on a source disk and the redundant
data on a target disk is inconsistent.
Action: Restart the Check Consistency task. If you
receive this alert again, verify the health of the array
disks included in the virtual disk. Review the alert
messages for significant alerts related to the array disks.
If you suspect that an array disk has a problem, replace
it and restore from backup.
1203 None
2343 The Check
Consistency
logging of
inconsistent
parity data is
disabled.
Wa rn ing/
Non-critical
Cause: The Check Consistency can no longer report
errors in the parity data.
Action: See the hardware documentation for more
information.
1203 None
2344 The virtual
disk
initialization
terminated.
Wa rn ing/
Non-critical
Cause: A user has cancelled the virtual disk
initialization.
Action: Restart the initialization.
1203 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number