Reference Guide
650 Storage Management Alert Reference
2336 Controller
event log: %1.
The %1
indicates a
substitution
variable. The
text for this
substitution
variable is
displayed with
the alert in the
Alert Log and
can vary
depending on
the situation.
Critical/
Failure/
Error
Cause: The text for this alert is generated by the
controller and can vary depending on the situation.
This text is from events in the controller event log that
were generated while Storage Management was not
running.
Action: See the hardware documentation for more
information.
754 None
2337 The controller
is unable to
recover cached
data from the
battery
backup unit
(BBU).
Critical/
Failure/
Error
Cause: The controller was unable to recover data from
the cache.
Action: Verify that the battery is charged and in good
health. When the battery charge is unacceptably low,
the battery cannot maintain cached data. Verify
whether the battery has met its recharge limit. The
battery may need to be recharged or replaced.
1154 None
2338 The controller
has recovered
cached data
from the
battery
backup unit
(BBU).
OK/Normal/
Informational
Cause: This alert is provided for informational
purposes.
Action: None.
1151 None
2339 The factory
default
settings have
been restored.
OK/Normal/
Informational
Cause: This alert is provided for informational
purposes.
Action: None.
751 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number