Reference Guide

648 Storage Management Alert Reference
2330 SAS port
report: %1.
The %1
indicates a
substitution
variable. The
text for this
substitution
variable is
displayed with
the alert in the
Alert Log and
can vary
depending on
the situation.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
751 None
2331 A bad disk
block has been
reassigned.
Wa rn ing/
Non-critical
Cause: The disk has a bad block. Data has been
readdressed to another disk block. No data loss has
occurred.
Action: Monitor the disk for other alerts or indications
of poor health. For example, you may receive alert 2306.
Replace the disk if you suspect there is a problem.
903 None
2332 A controller
hot plug has
been detected.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
751 None
2333 An enclosure
temperature
sensor
differential
has been
detected.
Wa rn ing/
Non-critical
Cause: The firmware has detected a temperature sensor
differential in the enclosure.
Action: Monitor the enclosure for other alerts related to
the temperature. For example, you may receive alerts
related to the fan or temperature probes. Verify the
health of the enclosure and its components. Replace
any component that is failed.
853 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number