Reference Guide

Storage Management Alert Reference 647
2325 The power
supply cable
has been
inserted.
OK/Normal/
Informational
Cause: This alert is provided for informational
purposes.
Action: None.
1001 None
2326 A foreign
configuration
has been
detected.
OK/Normal/
Informational
Cause: This alert is provided for informational
purposes. The controller has array disks that were
moved from another controller. These array disks
contain virtual disks that were created on the other
controller.
Action: None.
751 None
2327 The NVRAM
has corrupted
data. The
controller is
reinitializing
the NVRAM.
Wa rn ing/
Non-critical
Cause: The Non-Volatile Random-Access Memory
(NVRAM) has corrupted data. This may occur after a
power surge, a battery failure, or for other reasons.
The controller is reinitializing the NVRAM.
Action: None. The controller is taking the required
corrective action. If this alert is generated often (such
as during each reboot), then replace the controller.
753 None
2328 The NVRAM
has corrupt
data.
Wa rn ing/
Non-critical
Cause: The NVRAM has corrupt data. The controller is
unable to correct the situation.
Action: Replace the controller.
753 None
2329 SAS port
report: %1.
The %1
indicates a
substitution
variable. The
text for this
substitution
variable is
displayed with
the alert in the
Alert Log and
can vary
depending on
the situation.
Wa rn ing/
Non-critical
Cause: The text for this alert is generated by the
controller and can vary depending on the situation.
Action: Make sure the cables are attached securely. If
the problem is not resolved, replace the cable with a
valid cable according to SAS specifications. If the
problem persists, you may need to replace devices such
as the controller or EMM. Refer to the hardware
documentation for more information.