Reference Guide

Storage Management Alert Reference 645
2316 Diagnostic
message %1.
The %1
indicates a
substitution
variable. The
text for this
substitution
variable is
displayed with
the alert in the
Alert Log and
can vary
depending on
the situation.
Critical/
Failure/Error
Cause: A diagnostics test failed. The text for this alert
is generated by the utility that ran the diagnostics.
Action: See the documentation for the utility that ran
the diagnostics for more information.
754 None
2317 Background
initialization
(BGI)
terminated
due to loss of
ownership in a
cluster
configuration.
OK/Normal/
Informational
Cause: This alert is provided for informational
purposes.
Action: None.
1201 None
2318 Problems with
the battery or
the battery
charger have
been detected.
The battery
health is poor.
Wa rn ing/
Non-critical
Cause: The battery or the battery charger is not
functioning properly.
Action: Replace the battery pack.
1153 None
2319 Single-bit
ECC error.
The dual
in-line
memory
module
(DIMM) is
degrading.
Wa rn ing/
Non-critical
Cause: The DIMM is beginning to malfunction.
Action: Replace the DIMM to avoid data loss or data
corruption. The DIMM is a part of the controller
battery pack. Refer to your hardware documentation for
information on replacing the DIMM.
753 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number