Reference Guide
644 Storage Management Alert Reference
2314 The
initialization
sequence of
SAS
components
failed during
system
startup. SAS
management
and
monitoring is
not possible.
Critical/
Failure/
Error
Cause: Storage Management is unable to monitor or
manage SAS devices.
Action: Reboot the system. If problem persists, make
sure you have supported versions of the drivers and
firmware. You may need to reinstall Storage
Management or Server Administrator. You may be
missing some of the installation components.
104 None
2315 Diagnostic
message %1.
The %1
indicates a
substitution
variable. The
text for this
substitution
variable is
displayed with
the alert in the
Alert Log and
can vary
depending on
the situation.
OK/Normal/
Informational
Cause: This alert is provided for informational
purposes.
Action: None.
751 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number