Reference Guide

Storage Management Alert Reference 643
2311 The firmware
on the
enclosure
management
modules
(EMMs) is
not the same
version.
EMM0 %1
EMM1 %2
The %1 and
%2 indicate a
substitution
variable. The
text for this
substitution
variable is
displayed with
the alert in the
Alert Log and
can vary
depending on
the situation.
Wa rn ing/
Non-critical
Cause: The firmware on the EMM modules is not the
same version. It is required that both modules have the
same version of the firmware. This alert may be caused
when a user attempts to insert an EMM module that
has a different firmware version than an existing
module.
Action: Upgrade to the same version of the firmware on
both EMM modules.
853 None
2312 A power
supply in the
enclosure has
an AC failure.
Wa rn ing/
Non-critical
Cause: The power supply has an AC failure.
Action: Replace the power supply.
1003 None
2313 A power
supply in the
enclosure has
a DC failure.
Wa rn ing/
Non-critical
Cause: The power supply has a DC failure.
Action: Replace the power supply.
1003 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number