Reference Guide
Storage Management Alert Reference 641
2303 The enclosure
cannot
support both
SAS and
SATA array
disks. Array
disks may be
disabled.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
851 None
2304 An attempt to
hot plug an
enclosure
management
module
(EMM) has
been detected.
This type of
hot plug is not
supported.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
751 None
2305 The array disk
is too small to
be used for a
rebuild.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
901 None
2306 Bad block
table is 80%
full.
Wa rn ing/
Non-critical
Cause: The bad block table is the table used for
remapping bad disk blocks. This table fills as bad disk
blocks are remapped. When the table is full, bad disk
blocks can no longer be remapped which means that
disk errors can no longer be corrected. At this point,
data loss can occur. The bad block table is now 80% full.
Action: Back up your data. Replace the disk generating
this alert and restore from back up.
903 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number