Reference Guide

Storage Management Alert Reference 639
2294 A device has
been inserted.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
752, 802,
852, 902,
952, 1002,
1052,
1102,
1152,
1202
None
2295 A device has
been removed.
Critical/
Failure/
Error
Cause: A device has been removed and the system is no
longer functioning in optimal condition.
Action: Replace the device.
754, 804,
854, 904,
954, 1004,
1054,
1104,
1154,
1204
None
2296 An enclosure
management
module
(EMM) has
been inserted.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
851 None
2297 An enclosure
management
module
(EMM) has
been removed.
Critical/
Failure/
Error
Cause: An EMM has been removed.
Action: Replace the EMM. See the hardware
documentation for information on replacing the EMM.
854 None
2298 There is a bad
sensor on an
enclosure.
Wa rn ing/
Non-critical
Cause: The enclosure has a bad sensor. The enclosure
sensors monitor the fan speeds, temperature probes,
and so on.
Action: Refer to the hardware documentation for more
information.
853 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number