Reference Guide

634 Storage Management Alert Reference
2268 %1, Storage
Management
has lost
communicatio
n with this
RAID
controller and
attached
storage. An
immediate
reboot is
strongly
recommended
to avoid
further
problems. If
the reboot
does not
restore
communicatio
n, then there
may be a
hardware
failure. The
%1 indicates a
substitution
variable. The
text for this
substitution
variable is
displayed with
the alert in the
Alert Log and
can vary
depending on
the situation.
Critical/
Failure/
Error
Cause: Storage Management has lost communication
with a device. There may be faulty hardware or loose or
defective cables.
Action: Reboot the system. If the problem is not
resolved, check for hardware failures. Any failed
component must be replaced. Make sure the cables are
attached securely. Refer to the hardware
documentation for more diagnostics information.
104 None
2269 The array disk
Clear
operation has
completed.
OK/Normal/
Informational
Cause: This alert is provided for informational
purposes.
Action: None.
901 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number