Reference Guide

Storage Management Alert Reference 633
2265 A device is in
an unknown
state.
Wa rn ing/
Non-critical
Cause: The controller cannot communicate with a
device. The state of the device cannot be determined.
There may be a bad or loose cable. The system may also
be experiencing problems with the application
programming interface (API). There could also be a
problem with the driver or firmware.
Action: Check the cables. Verify that the controller has
a supported version of the driver and firmware. You can
download the most current version of the driver and
firmware from support.dell.com. Rebooting the system
may also resolve this problem.
753, 803,
853, 903,
953, 1003,
1053,
1103,
1153,
1203
None
2266 Controller log
file entry:%1.
The %1
indicates a
substitution
variable. The
text for this
substitution
variable is
displayed with
the alert in the
Alert Log and
can vary
depending on
the situation.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
751 None
2267 The controller
reconstruct
rate has
changed.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
751 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number