Reference Guide
626 Storage Management Alert Reference
2181 The controller
battery Learn
cycle will start
in % hours.
The %1
indicates a
substitution
variable. The
text for this
substitution
variable is
displayed with
the alert in the
Alert Log and
can vary
depending on
the situation.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
1151 None
2182 An invalid
SAS
configuration
has been
detected.
Critical/
Failure/
Error
Cause: The controller and attached enclosures are not
cabled correctly.
Action: See the hardware documentation for
information on correct cabling configurations.
754 None
2186 The controller
cache has
been
discarded.
Wa rn ing/
Non-critical
Cause: The controller has flushed the cache and any
data in the cache has been lost.This may occur when
the system has memory or battery problems that cause
the controller to distrust the cache. Although user data
may have been lost, this alert does not always indicate
that relevant or user data has been lost.
Action: Verify that the battery and memory are
functioning properly.
753 None
2187 Single-bit
ECC error
limit
exceeded.
Wa rn ing/
Non-critical
Cause: The system memory is malfunctioning.
Action: Replace the battery pack.
753 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number