Reference Guide

Storage Management Alert Reference 623
2166 The RAID
controller
firmware and
driver
validation was
not
performed.
The
configuration
file is out of
date or
corrupted.
Warning /
Non-critical
Cause: Storage Management is unable to determine
whether the system has the minimum required versions
of the RAID controller firmware and drivers. This
situation has occurred because a configuration file is
unreadable or missing data. The configuration file may
be corrupted.
Action: Reinstall Storage Management
753 None
2167 The current
kernel version
and the non-
RAID SCSI
driver version
are older than
the minimum
required
levels. See
readme.txt for
a list of
validated
kernel and
driver
versions.
Warning /
Non-critical
Cause: The version of the kernel and the driver do not
meet the minimum requirements. Storage
Management may not be able to display the storage or
perform storage management functions until you have
updated the system to meet the minimum
requirements.
Action: See the Readme file for kernel and driver
requirements. Update the system to meet the
minimum requirements and then reinstall Storage
Management.
103 None
2168 The non-
RAID SCSI
driver version
is older than
the minimum
required level.
See
readme.txt for
the validated
driver version.
Warning /
Non-critical
Cause: The version of the driver does not meet the
minimum requirements. Storage Management may not
be able to display the storage or perform storage
management functions until you have updated the
system to meet the minimum requirements.
Action: See the Readme file for the driver
requirements. Update the system to meet the
minimum requirements and then reinstall Storage
Management.
103 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number