Reference Guide
622 Storage Management Alert Reference
2162 Communicati
on regained
OK/Normal/
Informational
Cause: Communication with an enclosure has been
restored. This alert is provided for informational
purposes.
Action: None.
851 None
2163 Rebuild
completed
with errors
Critical /
Failure / Error
Cause: See "A Rebuild Completes with Errors" in
online help for more information.
Action: See "A Rebuild Completes with Errors" in
online help for more information.
904 690
2164 See
readme.txt for
a list of
validated
controller
driver versions
OK/Normal/
Informational
Cause: Storage Management is unable to determine
whether the system has the minimum required versions
of the RAID controller drivers.
Action: This alert is generated for informational
purposes. See the Readme file for driver and firmware
requirements. In particular, if Storage Management
experiences performance problems, you should verify
that you have the minimum supported versions of the
drivers and firmware installed.
101 None
2165 The RAID
controller
firmware and
driver
validation was
not
performed.
The
configuration
file cannot be
opened.
Warning /
Non-critical
Cause: Storage Management is unable to determine
whether the system has the minimum required versions
of the RAID controller firmware and drivers. This
situation may occur for a variety of reasons. For
example, the installation directory path to the
configuration file may not be correct. The
configuration file may also have been removed or
renamed.
Action: Reinstall Storage Management
753 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number