Reference Guide
620 Storage Management Alert Reference
2149 Bad block
extended
sense error
Warning /
Non-critical
Cause: A portion of an array disk is damaged. See the
online help for more information.
Action: See the online help for more information.
753 691
2150 Bad block
extended
medium error
Warning /
Non-critical
Cause: A portion of an array disk is damaged. See the
online help for more information.
Action: See the online help for more information.
753 691
2151 Asset tag
changed
OK/Normal/
Informational
Cause: A user has changed the enclosure asset tag.
This alert is provided for informational purposes.
Action: None.
851 None
2152 Asset name
changed
OK/Normal/
Informational
Cause: A user has changed the enclosure asset name.
This alert is provided for informational purposes.
Action: None.
851 None
2153 Service tag
changed
Warning /
Non-critical
Cause: An enclosure service tag was changed. In most
circumstances, this service tag should only be changed
by Dell support or your service provider.
Action: Ensure that the tag was changed under
authorized circumstances.
853 None
2154 Maximum
temperature
probe warning
threshold
value changed
OK/Normal/
Informational
Cause: A user has changed the value for the maximum
temperature probe warning threshold. This alert is
provided for informational purposes.
Action: None
1051 None
2155 Minimum
temperature
probe warning
threshold
value changed
OK/Normal/
Informational
Cause: A user has changed the value for the minimum
temperature probe warning threshold. This alert is
provided for informational purposes.
Action: None.
1051 None
2156 Controller
alarm has
been tested
OK/Normal/
Informational
Cause: The controller alarm test has run successfully.
This alert is provided for informational purposes.
Action: None.
751 None
2157 Controller
configuration
has been reset
OK/Normal/
Informational
Cause: A user has reset the controller configuration.
See the online help for more information. This alert is
provided for informational purposes.
Action: None.
751 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number