Reference Guide

618 Storage Management Alert Reference
2135 Array Manager
is installed on
the system
Warning /
Non-critical
Cause: Storage Management has been installed on a
system that has an Array Manager installation.
Action: Installing Storage Management and Array
Manager on the same system is not a supported
configuration. Uninstall either Storage Management or
Array Manager.
103 None
2136 Virtual disk
initialization
OK/Normal/
Informational
Cause: Virtual disk initialization is in progress.
This alert is provided for informational purposes.
Action: None.
1201 None
2137 Communicati
on timeout
Warning /
Non-critical
Cause: The controller is unable to communicate with
an enclosure. There are several reasons why
communication may be lost. For example, there may be
a bad or loose cable. An unusual amount of I/O may
also interrupt communication with the enclosure. In
addition, communication loss may be caused by
software, hardware, or firmware problems, bad or failed
power supplies, and enclosure shutdown.
When viewed in the Alert Log, the description for this
event displays several variables: controller name,
enclosure name, type of communication problem,
return code, and SCSI status.
Action: Check for problems with the cables. See the
online help for more information on checking the
cables. You should also check to see if the enclosure has
degraded or failed components. To do so, select the
enclosure object in the tree view and click the Health
subtab. The Health subtab displays the status of the
enclosure components. Verify that the controller has
supported driver and firmware versions installed and
that the enclosure management modules (EMMs) are
each running the same version of supported firmware.
853 688,
610, 611
2138 Enclosure
alarm enabled
OK/Normal/
Informational
Cause: A user has enabled the enclosure alarm. This
alert is provided for informational purposes.
Action: None.
851 676
2139 Enclosure
alarm disabled
OK/Normal/
Informational
Cause: A user has disabled the enclosure alarm.
Action: None.
851 677
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number