Reference Guide
612 Storage Management Alert Reference
2105 Controller
battery
recondition is
completed
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
1151 582
2106 Smart FPT
exceeded
Warning /
Non-critical
Cause: A disk on the specified controller has received a
SMART alert (predictive failure) indicating that the
disk is likely to fail in the near future.
Action: Replace the disk that has received the SMART
alert. If the array disk is a member of a non-redundant
virtual disk, then back up the data before replacing the
disk. Removing an array disk that is included in a
non-redundant virtual disk will cause the virtual disk to
fail and may cause data loss.
903 585
2107 Smart
configuration
change
Critical /
Failure / Error
Cause: A disk has received a SMART alert (predictive
failure) after a configuration change. The disk is likely
to fail in the near future.
Action: Replace the disk that has received the SMART
alert. If the array disk is a member of a non-redundant
virtual disk, then back up the data before replacing the
disk. Removing an array disk that is included in a
non-redundant virtual disk will cause the virtual disk to
fail and may cause data loss
904 586
2108 Smart warning Warning /
Non-critical
Cause: A disk has received a SMART alert (predictive
failure). The disk is likely to fail in the near future.
Action: Replace the disk that has received the SMART
alert. If the array disk is a member of a non-redundant
virtual disk, then back up the data before replacing the
disk. Removing an array disk that is included in a
non-redundant virtual disk will cause the virtual disk
to fail and may cause data loss.
903 587
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number