Reference Guide
608 Storage Management Alert Reference
2077 Virtual disk
format failed
Critical /
Failure / Error
Cause: An array disk included in the virtual disk failed.
Action: Replace the array disk. You can identify which
array disk has failed by locating the disk that has a
red "X" for its status. Rebuild the array disk. When
finished, restart the virtual disk format operation.
1204 539
2079 Virtual disk
initialization
failed
Critical /
Failure / Error
Cause: An array disk included in the virtual disk has
failed or a user has cancelled the initialization.
Action: If an array disk has failed, then replace the
array disk.
1204 541
2080 Array disk
initialize
failed
Critical /
Failure / Error
Cause: The array disk has failed or is corrupt.
Action: Replace the failed or corrupt disk. You can
identify a disk that has failed by locating the disk that
has a red “X” for its status. Restart the initialization.
904 542
2081 Virtual disk
reconfiguratio
n failed
Critical /
Failure / Error
Cause: An array disk included in the virtual disk has
failed or is corrupt. A user may also have cancelled the
reconfiguration.
Action: Replace the failed or corrupt disk. You can
identify a disk that has failed by locating the disk that
has a red “X” for its status. If the array disk is part of a
redundant array, then rebuild the array disk. When
finished, restart the reconfiguration.
1204 543
2082 Virtual disk
rebuild failed
Critical /
Failure / Error
Cause: An array disk included in the virtual disk has
failed or is corrupt. A user may also have cancelled the
rebuild.
Action: Replace the failed or corrupt disk. You can
identify a disk that has failed by locating the disk that
has a red “X” for its status. Restart the virtual disk
rebuild.
1204 544
2083 Array disk
rebuild failed
Critical /
Failure / Error
Cause: An array disk included in the virtual disk has
failed or is corrupt. A user may also have cancelled the
rebuild.
Action: Replace the failed or corrupt disk. You can
identify a disk that has failed by locating the disk that
has a red “X” for its status. Rebuild the virtual
disk rebuild.
904 545
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number