Reference Guide

606 Storage Management Alert Reference
2057 Virtual disk
degraded
Warning /
Non-critical
Cause 1: This alert message occurs when a physical disk
included in a redundant virtual disk fails. Because the
virtual disk is redundant (uses mirrored or parity
information) and only one physical disk has failed, the
virtual disk can be rebuilt.
Action 1: Configure a hot spare for the virtual disk if
one is not already configured. Rebuild the virtual disk.
When using a PowerEdge™ RAID Controller (PERC)
2/SC, 3/SC, 2/DC, 3/DCL, 3/DC, 3/QC, 4/SC, 4/DC,
4e/DC, 4/Di, 5/E or CERC ATA100/4ch controller,
rebuild the virtual disk by first configuring a hot spare
for the disk, and then initiating a write operation to
the disk. The write operation will initiate a rebuild of
the disk.
Cause 2: A physical disk in the array has been removed.
Action 2: If a physical disk was removed from the array,
either replace the disk or restore the original disk. You
can identify which disk has been removed by locating
the disk that has a red “X” for its status. Perform a
rescan after replacing the disk.
1203 509
2058 Virtual disk
check
consistency
started
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
1201 520
2059 Virtual disk
format started
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
1201 521
2061 Virtual disk
initialization
started
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
1201 523
2062 Array disk
Initialization
started
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
901
2063 Virtual disk
reconfiguratio
n started
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
1201 525
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number