Reference Guide

Storage Management Alert Reference 605
2050 Array disk
offline
Warning /
Non-critical
Cause: A physical disk in the array is offline. A disk can
be made offline during a Prepare to Remove operation
or because a user manually put the disk offline.
Action:
Perform a rescan. You can also select the offline
disk and perform a Make Online operation.
903 502
2051 Array disk is
degraded
Warning /
Non-critical
Cause: An array disk has reported an error condition
and may be degraded. The array disk may have reported
the error condition in response to a consistency check
or other operation.
Action: Replace the degraded array disk. You can
identify which disk is degraded by locating the disk that
has a red "X" for its status. Perform a rescan after
replacing the disk.
903 503
2052 Array disk
inserted
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
901 504
2053 Virtual disk
created
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
1201 505
2054 Virtual disk
deleted
Warning /
Non-critical
Cause: A virtual disk has been deleted. "Performing a
Reset Configuration" may detect that a virtual disk has
been deleted and generate this alert.
Action: None.
1203 506
2055 Virtual disk
configuration
changed
OK/Normal/
Informational
Cause: This alert is provided for informational
purposes.
Action: None.
1201 507
2056 Virtual disk
failed
Critical /
Failure / Error
Cause: One or more physical disks included in the
virtual disk have failed. If the virtual disk is
non-redundant (does not use mirrored or parity data),
then the failure of a single physical disk can cause the
virtual disk to fail. If the virtual disk is redundant, then
more physical disks have failed than can be rebuilt
using mirrored or parity information.
Action:
Create a new virtual disk and restore from a
backup.
1204 508
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number