Reference Guide
Traps 571
Understanding the Trap Description
Table 25-1 lists in alphabetical order each line item that may appear in the trap description.
Table 25-1. Trap Description Reference
Description Line Item Explanation
Action performed was: <
Action
> Specifies the automatic server recovery action that was performed,
for example:
Action performed was: Power cycle
Action requested was:
<Action>
Specifies the user initiated host control action that was requested,
for example:
Action requested was: Reboot, shutdown OS first
Additional details: <Additional
details for the events>
Specifies possible additional details about the specified device, for
example:
Additional details:
Memory device: DIMM_1A Serial number: 11111111
Memory device: DIMM_1B Serial number: 22222222
<
Additional power supply status
information
>
Specifies any additional power supply information pertaining to
the event, for example:
Power supply input AC is off, Power supply POK
(power OK) signal is not normal, Power supply
is turned off
Battery sensor status: <status> Specifies the status reported by the battery sensor, for example:
Battery sensor status: Predictive failure
Chassis intrusion state:
<
Intrusion state
>
Specifies the chassis intrusion state (open or closed), for example:
Chassis intrusion state: Open
Chassis location:
<
Name of chassis
>
Specifies the name of the chassis that generated the message,
for example:
Chassis location: Main System Chassis
Configuration error type:
<type
of configuration error>
Specifies the type of configuration error that occurred,
for example:
Configuration error type: Revision mismatch
Current sensor value (in Amps):
<
Reading
>
Specifies the current sensor value in amps, for example:
Current sensor value: 7.853