User's Manual

omconfig: Managing Components Using the Instrumentation Service 95
Table 5-11 shows the valid parameters for the command.
omconfig chassis remoteaccess
NOTE: This command is applicable to PowerEdge x8xx and x9xx systems only.
Use the omconfig chassis remoteaccess command to configure:
Remote access on a local area network (LAN).
The serial port for BMC or RAC, whichever is installed.
The BMC or RAC on a serial over LAN connection.
Terminal settings for the serial port.
Advanced settings for a serial over LAN connection.
Information on a BMC or RAC user.
NOTE: You have to enter the user ID to configure user information.
Ty p e :
omconfig chassis remoteaccess
Table 5-11. omconfig chassis memorymode
name=value pair 1 Description
index=<n> Number of the chassis where the memory module resides (the default is
chassis 0, the main system chassis).
redundancy=spare |
mirror | disabled | raid5
Spare disables the memory module that has a correctable memory event
and copies the failing module’s data to a spare bank.
Disabled indicates that the system is not to use other available memory
modules if uncorrectable memory events are detected.
Mirror switches the systems to a mirrored copy of the memory if the
failing module has an uncorrectable memory event. In mirror mode, the
operating system does not switch back to the original module until the
system reboots.
RAID5 is a method of system memory configuration. This is logically
similar to the RAID 5 mode used in hard drive storage systems. This
memory mode gives you an extra level of memory checking and error
recovery at the expense of some memory capacity. The RAID mode
supported is RAID level 5 striping with rotational parity.