User's Manual
omconfig: Managing Components Using the Instrumentation Service 83
vlanenable=true | false true: Enables the virtual
LAN identification.
false: Disables the virtual
LAN identification.
vlanid=number number: Virtual LAN identification in
the range of 1 to 4094.
vlanpriority=number number: Priority of virtual LAN
identification in the range of 0 to 7.
config=serial baudrate=9600 | 19200 | 38400 |57600
| 115200
9600: Sets connection speed to 9600
bits per second.
19200:Sets connection speed to 19200
bits per second.
38400: Sets connection speed to
38400 bits per second.
57600: Sets connection speed to
57600 bits per second.
115200: Sets connection speed to
115200 bits per second.
NOTE: Baud rates of 9600, 19200, 38400,
and 57600 are supported on PowerEdge
1800,1850, 2800, and 2850 systems.
Baud rates of 9600, 19200, and 57600 are
supported on PowerEdge 1900, 1950,
1955, 2900, and 2950 systems.
Baud rate of 115200 is supported on
certain systems that have a DRAC 5
installed.
flowcontrol=none | rtscts none: No control over the flow of
communication through the serial
port.
rtscts: RTS is ready to send and
CTS is clear to send.
Table 5-3. omconfig chassis bmc (continued)
name=value pair 1
config=
name=value pair 2 Description