User's Manual

82 omconfig: Managing Components Using the Instrumentation Service
ipsource=static | dhcp |
systemsoftware
static: Static if the IP address of the
BMC LAN interface is a fixed,
assigned IP address.
dhcp: DHCP if the source of the
IP address of the BMC LAN interface
is the dynamic host
configuration protocol.
systemsoftware: System software if
the source of the IP address of the
BMC LAN interface is from the
system software.
NOTE: Not all commands may be
supported on the system.
nicselection=nic1 | teamednic1nic2 |
dracnic
nic1: Enables NIC 1.
teamednic1nic2: Enables NIC
teaming functionality.
dracnic: Enables DRAC NIC if DRAC
5 is installed.
NOTE: The option nicselection is
supported only on PowerEdge 1900,
1950, 1955, 2900, and 2950 systems.
NOTE: If there are multiple embedded
NICs on your system, you can select the
NIC teaming option to share the BMC
management traffic between them.
privilegelevel=administrator | operator
| user
administrator: Sets the maximum
privilege level that can be accepted on
a LAN channel to Administrator.
operator: Sets the maximum privilege
level that can be accepted on a
LAN channel to Operator.
user: Sets the maximum privilege
level that can be accepted on a
LAN channel to User.
subnet=Subnet subnet: Sets a subnet mask if you have
selected static as the IP address source
for the BMC LAN interface.
Table 5-3. omconfig chassis bmc (continued)
name=value pair 1
config=
name=value pair 2 Description