User's Manual

Using the Storage Management Service 205
Example Syntax
For example, you may want to reset the thresholds for all temperature probes in enclosure 2 on
controller 1.
Example for SAS Controllers
In this example, the temperature probes reside in enclosure 3 attached to connector 2 on controller 1. To
reset the thresholds for all temperature probes, enter:
omconfig storage enclosure action=resetalltempprobes controller=1
enclosure=2:3
omconfig Blink
Use the following omconfig command to blink the light-emitting diodes (LEDs) on the enclosure.
Complete Syntax
omconfig storage enclosure action=blink controller=id enclosure=
<ENCLOSUREID>
where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.
Example for SCSI, SATA, and ATA Controllers:
For example, to blink the LEDs for the enclosure attached to connector 2 on controller 1, enter:
omconfig storage enclosure action=blink controller=1 enclosure=2
Example for SAS Controllers:
For example, to blink the LEDs for enclosure 3 attached to connector 2 on controller 1, enter:
omconfig storage enclosure action=blink controller=1 enclosure=2:3