User's Manual
190 Using the Storage Management Service
Example Syntax
In this example, you want to unblink array disk 0 on connector 0 of controller 1. On a SAS controller, the
array disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers:
To unblink the array disk described in this example, enter:
omconfig storage adisk action=unblink controller=1 adisk=0:0
Example for SAS Controllers:
To unblink the array disk described in this example, enter:
omconfig storage adisk action=unblink controller=1 adisk=0:2:0
omconfig Prepare to Remove Array Disk
Use the following omconfig command syntax to prepare an array disk for removal:
Complete Syntax
omconfig storage adisk action=remove controller=id adisk=<ADISKID>
where id is the controller ID. The <ADISK> variable specifies the array disk.
To obtain these values, enter omreport storage controller to display the controller IDs and then enter
omreport storage adisk controller=ID to display the IDs for the array disks attached to the controller.
Example Syntax
In this example, you want to prepare array disk 3 on connector 0 of controller 1 for removal. On a SAS
controller, the array disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers:
To prepare to remove the array disk described in this example, enter:
omconfig storage adisk action=remove controller=1 adisk=0:3
Example for SAS Controllers:
To prepare to remove the array disk described in this example, enter:
omconfig storage adisk action=remove controller=1 adisk=0:2:3
omconfig Initialize Array Disk
Use the following omconfig command syntax to initialize an array disk.