User's Manual
Using the Storage Management Service 189
omconfig Blink Array Disk
You can blink the light (light emitting diode or LED display) on one or more array disks attached to a
controller. Use the following omconfig command syntax to blink one or more array disks.
Complete Syntax
action=blink controller=ID action=blink controller=id adisk=
<ADISKID>
where id is the controller ID. The <ADISK> variable specifies the array disk.
To obtain these values, enter omreport storage controller to display the controller IDs and then enter
omreport storage adisk controller=ID to display the IDs for the array disks attached to the controller.
Example Syntax
In this example, you want to blink array disk 0 on connector 0 of controller 1. On a SAS controller, the
array disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers:
To blink the array disk described in this example, enter:
omconfig storage adisk action=blink controller=1 adisk=0:0
Example for SAS Controllers:
To blink the array disk described in this example, enter:
omconfig storage adisk action=blink controller=1 adisk=0:2:0
omconfig Unblink Array Disk
You can unblink the light (light emitting diode or LED display) on one or more array disks attached to a
controller. Use the following omconfig command syntax to unblink one or more array disks.
Complete Syntax
omconfig storage adisk action=unblink controller=id adisk=<ADISKID>
where id is the controller ID. The <ADISK> variable specifies the array disk.
To obtain these values, enter omreport storage controller to display the controller IDs and then enter
omreport storage adisk controller=ID to display the IDs for the array disks attached to the controller.
action=cancelrebuild controller=id adisk=<ADISKID>
action=removedeadsegments controller=id adisk=<ADISKID>
Table 9-23. omconfig Array Disk Commands (continued)
Required Command Levels (1, 2, 3) Optional name=value pairs